DefiMax biphasic clinical defibrillator

A DefiMax biphasic clinical defibrillator with a high-brightness color screen, displaying ECG readings and controls for manual defibrillation, cardioversion, and other monitoring features.

The basic configuration of the device allows a manual defibrillation, cardioversion and ECG measurement. It can be also equipped with cardioversion and ECG measurement. It can be also equipped with additional modules: pulse oximetry (SpO2), non-invasive blood pressure (NIBP) and with an option of transcutaneous pacemaker and AED mode.

The large, 6.5-inch high-brightness colour screen provides legible information about defibrillation and stimulation, as well as about measured patient’s parameters.

EMTEL DefiMax – Technical Parameters

General Parameters

  • Power supply: 110–230 VAC ±10%, 50/60 Hz
  • Internal battery: 12 VDC
  • Safety class: II, CF, BF
  • Safety standards:
    • MDD 93/42/EEC
    • 2007/47/EC
    • EN 60601-1, EN 60601-1-2, EN 60601-2-4
  • Weight: 6.0 kg (without paddles)
  • Dimensions: 298 × 312 × 260 mm

Operating Modes

  • Manual mode
  • Cardioversion mode
  • AED mode
  • Monitoring mode
  • Pacer mode
  • Service mode

Display

  • Type: 6.5″ color TFT LCD
  • Resolution: 640 × 480 pixels
  • Display: Digital values and waveforms

Thermal Recorder

  • Paper width: 57 mm
  • Modes: Automatic and manual
  • Number of channels: 3
  • Sweep speed: 25 and 50 mm/s
  • Printout length: 15 seconds

A medical professional holding the DefiMax biphasic defibrillator in a clinical setting, displaying its screen with ECG readings and controls.

Monitor Module

  • Number of channels: 4
  • Sweep speed: 3.125 to 50 mm/s
  • Trends storage: Minimum 6 hours
  • Archive: Minimum 6 hours
  • Events archive: Minimum 500 events
  • Alarms: For all monitored parameters

ECG Module

  • Leads: I, II, III, aVR, aVL, aVF, Vn (12-lead ECG optional)
  • CMRR: > 100 dB
  • Filters: Diagnostic, monitoring, transport
  • Sensitivity: 2.5 – 40 mm/mV
  • Heart rate range: 15 – 300 bpm
  • QRS signaling: Acoustic and optical
  • Protection: Input protected against defibrillator shocks and high-frequency interference

Pacer Module (Optional)

  • Impulse shape: Monophasic
  • Modes: On-demand and fixed-rate
  • Output current: 0 – 200 mA
  • Pacing rate: 30 – 180 pulses/min
  • Impulse width: 5 – 40 ms

SpO₂ Module – Nellcor OxiMax™ (Optional)

  • Measurement range: 0 – 100%
  • Accuracy (70–100%): ±2 digits
  • Accuracy (60–80%): ±3 digits
  • Pulse rate: 20 – 300 bpm
  • Features: Motion and low-perfusion tolerant
  • Display: Plethysmographic waveform

NIBP Module (Optional)

  • Measurement range: 10 – 300 mmHg
  • Modes: Manual, automatic, STAT
  • Auto-mode repetition time: 1 – 480 minutes